fbpx ADView 2® | American Diagnostic Corporation
Overview

The ADC® ADView® 2 Modular Diagnostic Station

The ADView® 2 Modular Diagnostic Station is being discontinued.

Limited quantities of blood pressure base units (9005BP) and blood pressure units with temperature modules (9005BPTO) are still available.

Our next generation unit, the ADView® 2.6, is also in stock and shipping now.

Please note:

  • Support for the ADView 2 will continue for as long as replacement parts remain available.
  • ADView 2 platforms and accessories will also remain available for purchase while supplies last.
  • Replacement blood pressure cuffs and cuff sets will remain fully stocked and available.

If you have any questions, please contact your sales representative or ADC Customer Service at 1-800-ADC-2670 or info@adctoday.com.

Ordering

The ADView® 2 Modular Diagnostic Station is being discontinued.

Limited quantities of the 9005BP and 9005BPTO configurations are still available.

ADView 2 platforms and accessories will also remain available for purchase while supplies last.

Replacement blood pressure cuffs and cuff sets will remain fully stocked and available.

ADC® ADView® 2 Diagnostic Station Configurations

ADView 2 BPBlood pressure base unit9005BP
ADView 2 BP/TempBlood pressure base unit with temperature module9005BPTO
ADView 2 BP/SpO2*Blood pressure base unit with ChipOx Nellcor-compatible SpO2 module9005BPS DISCONTINUED
ADView 2 BP/Masimo SETBlood pressure base unit with Masimo SET SpO2 module9005BPSM DISCONTINUED
ADView 2 BP/Masimo SET/TempBlood pressure base unit with Masimo SET SpO2 module and temperature module9005BPSMTO DISCONTINUED

BP base unit includes: Rechargeable lithium-ion battery; U.S. power cord; 10-foot length of tubing; Adult and Large Adult Adcuff+ cuffs; Mini-USB to USB Cable; Quick Reference Guide; Quickstart Guide.
Temperature module includes: Oral/axillary probe and well (blue) and box of 20 probe covers.

ADC ADView 2 Mounting Platforms

Desktop Caddy*Desktop caddy plate and hardware9005D
Wall Mount with BasketWall mount plate and hardware with cuff/accessory storage basket9005W
Mobile Stand with BasketFive-legged mobile stand and hardware with cuff/accessory basket9006M

*Desktop unit is self standing. Optional desktop caddy helps keep cuffs and cords organized.

ADC ADView 2 Modules (When Sold Separately)

Temperature Module, OralTemperature module with oral/axillary probe and well (blue) and box of 20 probe covers9005TO
Temperature Module, RectalTemperature module with rectal probe and well (red) and box of 20 probe covers9005TR DISCONTINUED
SpO2 Module, ChipOx*ChipOx Nellcor-compatible SpO2 module with reusable adult finger sensor and cord9005S DISCONTINUED
SpO2 Module, Masimo SETMasimo SET SpO2 module with reusable adult finger sensor and cord9005SM DISCONTINUED

ADC ADView 2 Networking and Hardware Accessories

Printer Paper, 10 RollsTen rolls of paper for thermal printer9005PAPER
Printer Shelf for Mobile StandPrinter shelf and hardware for mobile stand mounting9005PSHELF
Linear ScannerLinear barcode scanner9005SCANL
2D Scanner2D barcode scanner9005SCAN2D

ADC ADView 2 Adcuff Options

Adult, NavyAdult Adcuff+, navy, with bayonet connector; limb range 23-40 cm9005-11AN-1MB
Child, GreenChild Adcuff+, green, with bayonet connector; limb range 13-19.5 cm9005-9CGR-1MB
Small Adult, Royal BlueSmall Adult Adcuff+, royal blue, with bayonet connector; limb range 19-27 cm9005-10SARB-1MB
Large Adult, Burgundy Large Adult Adcuff+, burgundy, with bayonet connector; limb range 34-50 cm9005-12XBD-1MB
Thigh, Brown Thigh cuff, brown, with bayonet connector; limb range 40-66 cm9005-13TBR-1MB
Pediatric Cuff Kit Includes Child, Small Adult, and Adult cuffs9005CKP
Adult Cuff Kit Includes Small Adult, Adult, and Large Adult cuffs9005CKA
Complete Cuff Kit Includes Child, Small Adult, Adult, Large Adult, and Thigh cuffs9005CK
BP Hose 10-foot blood pressure hose with metal bayonet connectors.9005BPC

All cuffs equipped with male bayonet.

ADC ADView 2 Pulse Oximetry Accessories

SpO2 Finger Sensor, AdultReusable adult finger sensor with 8-foot cable and DB-9M connector; Nellcor-compatible sensor DS-100A9005SP DISCONTINUED
SpO2 Finger Sensor, PediatricReusable pediatric finger sensor with 8-foot cable.9005SPC

ADC ADView 2 Thermometry Accessories

(Covidien Filac™ 3000)

Thermometer Probe Covers (500)20 per box, 25 boxes per case9000TP
Oral/Axillary Temperature ProbeOral/axillary (blue) probe with 9-foot (2.7 m) extended cord9000TOP
Oral/Axillary Temperature WellRear piece of the temperature module that holds the oral/axillary probe and box of probe covers9005TWB
Oral/Axillary Temperature KitIncludes oral (blue) probe, oral (blue) well, and box of probe covers9005TOK
Rectal Temperature ProbeRectal (red) probe with 9-foot (2.7 m) extended cord9000TRP DISCONTINUED
Rectal Temperature WellRear piece of the temperature module that holds the rectal probe and box of probe covers9005TWR
Rectal Temperature KitIncludes rectal (red) probe, rectal (red) well, and box of probe covers9005TRK DISCONTINUED

ADC ADView 2 Power Supply Accessories

Rechargeable Lithium-Ion Battery 7.2V, 6600mAh internal lithium-ion battery 9005BAT
Power Cord, U.S., 120VACPower or mains lead with Type B, NEMA 5-15, three-pin plug, 8.2-foot (2.5 m) length9005PC
Power Cord, Euro, 240VACPower or mains lead with Type E and F hybrid, CEE 7/7, two-pin plug, 8.2-foot (2.5 m) length9000PCEU
Power Cord, U.K., 240VACPower or mains lead with Type G, BS1363, three-pin plug, 8.2-foot (2.5 m) length9000PCUK
Power Cord, Australia, 120VACPower or mains lead with Type C, IEC320, three-pin plug, 8.2-foot (2.5 m) length9000PCAU

ADC ADView 2 Calibration Accessories

Y Test KitY tubing with inflation bulb, valve, and connectors991
Calibration plug for temperature moduleCalibration plug for testing of temperature module (Covidien part number 500099)9005TCP

*This product not available for sale in Canada

Technical

Technical Specs

SpO2
Saturation Normal (no motion):70-100%Arms ± 2%
Saturation Motion:N/A
Low Perfusion:N/A
Pulse Heart rate:20-300 BPM: ±3 BPM
Pulse Heart rate w/motion:20-300 BPM: ±3 BPM
Temperature
Temperature Accuracy:Quick Mode (Oral): ± 0.3°C
Temperature Accuracy:Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy:Direct Mode ± 0.1°C
Response Time:4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution:0.1°C
Blood Pressure
Range:Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP):Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa.
Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part.

It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.

Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg

*Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner

Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
Limited Warranty
Main unit:
SpO2 modules:
Temp modules:
3 years
Blood Pressure Cuffs:3 years
Battery:1 year
Accessories (SpO2 sensors,
temp probes, BP hose, etc):
90 days
Software
ADView® 2 Driver for Windows - 32 bitDownload
ADView® 2 Driver for Windows - 64 bitDownload
FAQ

ADView 2 FAQ

Q. Is the Nellcor SpO2 module still available?
A. Due to a manufacturing shortage, the ChipOx Nellcor-compatible SpO2 module is no longer available. New purchases of the Adview 2 Modular Diagnostic Station that include this component will be automatically upgraded to a Masimo SET SpO2 module. You can read more here.
Q. Once charged, how long will the battery run?
A. When fully charged, the ADView 2 is designed to run on internal battery power for 200 measurement cycles (BP, temperature, and SpO2 measurements) before requiring recharge. When only the bottom segment of the battery symbol is illuminated, there is between 11 percent and 40 percent battery power remaining.
Q. Does the ADView 2 power down automatically?
A. When no measurements have been taken or buttons pressed for one hour, the device will automatically power down and enter the Sleep Mode, a low-power state. This is considered off.
Q. What do the different beeps mean?
A. During operation, you may hear a short beep, a long beep, or combinations of these. For example:
  • One long beep (approximately three seconds) means the successful end of blood pressure measurement.
  • One short beep (approximately one second) means your power-up or power-down is complete.
  • One short beep and one long beep occur when you abort a blood pressure measurement by pressing the Start/Stop button. One short beep sounds first, then, after the pressure has been completely dumped from the cuff, you will hear one long beep.
  • Four short beeps mean there is an error.
  • Three long beeps mean there is a severe hardware error.
Q. How many measurements can be stored in memory?
A. The ADView 2 can store 99 unique sets of measurements. After the 99th measurement has been saved, the next measurement will have the Memory Location Identifier label “01” and will overwrite the most recent measurement (measurement “99”). After all results are cleared from the memory, the Memory Location Identifier also will return to “01.”
Q. Can modules and accessories be added later?
A. Definitely! The ADView 2 is still the only truly modular diagnostic station that grows with your needs. Start with blood pressure and choose temperature or pulse oximetry options at the time of purchase; we’ll ship your ADView 2 fully configured and ready to go. Or add new modules and accessories in the field, anytime, as you need them. Our user-expandable, connect-and-go construction makes upgrading effortless.
Q. Can EMR connectivity be established at a later date if not enabled as part of initial configuration?
A. Yes, EMR settings can be accessed any time via the Advanced Configuration Application.
Q. How do I get to the Advanced Configuration Application?
A. To access the Advanced Configuration Application you must first download and install the device driver, then connect your ADView 2 to a Windows-based computing device using a mini-USB to USB connection cable (one of these cables is included with the blood pressure base unit). Connect the mini-USB end of the cable to the plug on the back of your ADView 2 and the USB end to your computer. Then, using your computer’s web browser, navigate to http://model260.local to launch the Advanced Configuration Application.
Download Driver for Windows - 32bit Download Driver for Windows - 64bit
Q. Why don’t the MAP measurements show on the display?
A. The ability to measure MAP must be turned on using the Advanced Configuration Application. It is turned off by default at the factory. If MAP is enabled, the results will alternate with heart rate results on the display screen. Note that MAP results are only validated for use outside of the United States.
Q. Why isn’t heart rate data showing on the display?
A. If the device is configured to use the SpO2 sensor as the pulse rate source but the sensor is not attached to the patient, heart rate data will not show up on the display. Only dashes will appear (or MAP results if MAP measurement is enabled).
Q. Does the ADView 2 use encryption?
A. Yes, the ADView 2 offers end-to-end SSL encryption from the base unit to the EMR system. If SSL is selected, no plain text data is transferred between the ADView 2 and the EMR system. SSL can be selected using the Advanced Configuration Application. For more information, download the Advanced Configuration Application User Manual..
Q. Is data transferred by Wi-Fi encrypted?
A. WPA(2) Wi-Fi encryption may be used to provide encryption on the wireless link for any data transmitted over the Wi-Fi. WPA(2) encryption only encrypts the wireless portion of the transfer; data on the wired hospital network is unencrypted. To ensure end-to-end encryption, SSL must be used.
Q. Is data stored on the ADView encrypted?
A. The data contained within the ADView 2 is not encrypted, but it is protected via password and/or encrypted communication channels.
Q. How do I turn on the ADView 2?
A. Simply press the power button on the left side of the unit. You’ll see a blue light around the Selection Knob whenever the device is powered on.
Q. Can the ADView 2 be used on neonates?
A. No. The ADView2 is validated for use on patients age three and older.
Q. What method of blood pressure measurement does the ADView 2 use?
A. The ADView 2 takes automated BP measurements using the oscillometric method. A manual mode is also available, allowing you to capture blood pressure with a stethoscope using the traditional auscultatory method.
Q. How long is the warranty?
A. ADView 2 blood pressure, temperature, and SpO2 modules come with a three-year warranty. Adcuff+ Blood pressure cuffs come with a three-year warranty. The desktop caddy, wall mount, and mobile stand have a two-year warranty. Accessories (e.g., sensors, probes) offer a 90-day warranty.
Q. Can I use the ADView 2 to measure blood pressure during a stress test?
A. Although your ADView 2 is a robust device that has been manufactured with motion tolerance, it is not intended for use during stress testing.
Q. How do I clean the ADView 2?
A. The ADView 2 requires only minimal cleaning. Wipe it down occasionally with a soft, damp cloth. Never immerse the device or apply cleaning fluid or solvents.
Q. How do you clean the cuffs that come with the ADView 2?
A. Adcuff+ nylon cuffs can be easily cleaned with most major brands of alcohol or bleach-based wipes. See the user manual for more information.

If you have any additional questions, please give us a call at 1-800-ADC-2670.